The proficiency testing activity serves as a crucial technical tool for laboratory accreditation bodies and management departments to assess the competence of laboratories, while also functioning as an essential external quality assurance mechanism. By actively participating in regular proficiency testing activities, we have successfully validated the accuracy and scientific validity of our laboratory's test results, thereby enhancing our confidence in delivering reliable data and test reports to our clients.

 

能力验证技术分析:

 

1、关于“四线法”测量

不少实验室在调查表中回答“两线法”,通常对微小电阻测量均采用“四线法”测量方式,它是消除接触电阻对测量结果影响的有效手段,而“两线法”就很难消除接触电阻带来的误差。

 

2、测试夹子夹持问题

微电阻的“四线法”测量原理要求4个测试夹子不得随意夹持,若把两个电压测试夹子夹在两个电流测试夹子上,这实际上等于变成“两线法”测量,如果在接触电阻较大的情况下就非常容易造成测试结果不准确。对样品的接线端夹持不紧也会导致测试结果偏大。

 

3、零位电阻值过大问题

在测试端子短接校“0 ”时,其阻值在3毫欧以下普遍认为较佳,如果零位电阻值较大,达到12mΩ、15mΩ甚至更大,可能是测试导线或连接端子有问题,应予以维修或更换。同时,也应对零位值进行计量并给出修正值,以满足对微小电阻的精确测量。